====== Appliance installation instruction ====== {{indexmenu_n>2}} A typical connection diagram for **x86 server hardware**: {{ dpi:dpi_brief:install_point_ssg:equipment_scheme.png?nolink&1200 |}} Cards with [[dpi:dpi_brief:dpi_requirements#minimum_requirements|10/25/40/100 network ports]] are placed in **slots 1-10**\\ Each slot has a unique PCIe bus identifier, e.g. **02:00**.\\ Each port has a unique identifier on the card, e.g: **02:00.0, 02:00.1, 02:00.2, 02:00.3**.\\ **Example of interfaces orientation in pairs:** # In, to the subscriber side - port 02:00.0, 02:00.2 in_dev=02:00.0:02:00.2 # Out, to the Internet side - port 02:00.1, 02:00.3 out_dev=02:00.1:02:00.3 Port configuration is described in the section [[dpi:dpi_components:platform:dpi_config|DPDK Interfaces Configuration]]. Ports **mg0, mg1** are used for SSH management, IPFIX sending (Full flow, NAT log, ClickStream), integration with Radius/PCRF . For fault tolerance, they are combined in LAG. The **bmc** port is used to connect to the BMC server controller. Each server has two power supplies **psu1, psu2** for power redundancy.